Enclosed Circuit Breakers (ECBs)

Your content goes here. Edit or remove this text inline or in the module Content settings. You can also style every aspect of this content in the module Design settings and even apply custom CSS to this text in the module Advanced settings.

Reliable, Code-Compliant Disconnect Solutions for Every Application

Keep people and equipment safe—and get power back online fast—with MCXP Solutions’ Enclosed Circuit Breakers. Built with individually UL-rated components and engineered for real-world reliability, our ECBs deliver a code-compliant means of disconnect for virtually any commercial or industrial application. We stock common frames and enclosure styles for quick-ship turnarounds, and we customize builds to your one-line, spec, and site conditions.

What Is an Enclosed Circuit Breaker?

An enclosed circuit breaker is a molded-case circuit breaker (MCCB) mounted inside a protective NEMA-rated enclosure. It provides local overcurrent protection and a lockable, visible means of disconnect, often required by code for service entrances, feeders, and large equipment. MCXP standardizes on rugged enclosures and proven MCCB platforms so you get dependable performance with shorter lead times.

Standard Scope & Ratings

  • ^
    Frames: 100A–4000A
  • ^
    Voltage classes: 240–600VAC (application dependent)
  • ^
    Enclosure ratings: NEMA 1 / 3R / 4 / 12 (standard)
  • ^
    Materials: Painted carbon steel, Stainless 304/316, fiberglass options on request
  • ^
    Operating mechanisms: Flange or rotary handle (stocked)
  • ^
    Neutral: Solid or switched neutral available
  • ^
    Components: All individually UL-rated
  • ^
    Service Entrance Rated with standard components*

*Final labeling and rating depend on specific bill-of-materials and jurisdictional requirements.

Why Choose MCXP Enclosed Breakers?

Quick-Ship Advantage

Factory lead times on disconnects can stall projects. MCXP carries common frame sizes, operators, and enclosures so we can build, test, and ship fast—without compromising safety or documentation.

Built for Your Environment

From climate-controlled mechanical rooms to coastal sites and washdown areas, we package breakers in the right enclosure for the job: NEMA 1 (indoor), 3R (outdoor), 4 (hose-down), 4X (corrosion-resistant stainless), and 12 (dust-tight). Hazardous-location builds (NEMA 7/9) are available for classified areas.

Flexible Operation & Integration

Pick flange or rotary operators, add door interlocks, and specify auxiliary contacts for remote status. We also provide cam-lock inlets, Kirk®/Castell® key interlocks, and labeling packages to fit your lockout/tagout and switching procedures.

Proven Protection

Every ECB is configured around a high-reliability MCCB platform, with options for ground-fault protection (GFP), 100% rated breakers, and Arc Flash Reduction Maintenance modes (ERMS/RELT/DAS/ARMS) to help reduce incident energy during maintenance.

Applications

  • ^
    Service entrance disconnects (where a main is required at point of entry)
  • ^
    Feeder protection for switchboards, panelboards, MCCs, and distribution gear
  • ^
    Local equipment disconnects for pumps, fans, compressors, and process skids
  • ^
    Temporary/backup power tie-ins with cam-lock accessories
  • ^
    Harsh and hazardous locations (stainless 304/316, NEMA 4X, or NEMA 7/9 builds)

Configuration Options

  • ^
    Service entrance disconnects (where a main is required at point of entry)
  • ^
    Feeder protection for switchboards, panelboards, MCCs, and distribution gear
  • ^
    Local equipment disconnects for pumps, fans, compressors, and process skids
  • ^
    Temporary/backup power tie-ins with cam-lock accessories
  • ^
    Harsh and hazardous locations (stainless 304/316, NEMA 4X, or NEMA 7/9 builds)

Configuration Options

Protection & Performance
  • ^
    100% rated breakers (per frame/temperature rise conditions)
  • ^
    Ground-Fault Protection (factory settings or field-adjustable)
  • ^
    Arc-flash reduction (ERMS/RELT/DAS/ARMS) test switch and indication
Controls & Monitoring
  • ^
    Shunt trip, undervoltage release, auxiliary and alarm contacts
  • ^
    Pre-wired control terminal blocks, engraved legends, multi-language labeling
  • ^
    Metering windows and CT provisions on larger frames
Safety & Access
  • ^
    Handle padlocking, door interlocks, defeat provisions (where code-permitted)
  • ^
    Dead-front barriers, finger-safe terminals, lug kits
  • ^
    Space heaters, drain/breather, sunshields (outdoor)
Enclosures & Hardware
  • ^
    NEMA 1/3R/4/12 painted steel (standard)
  • ^
    Stainless steel 304/316 (NEMA 4X) for washdown/corrosive sites
  • ^
    Explosion-proof (NEMA 7/9) for classified areas
  • ^
    Hinged doors, lift-off or split covers; wall or floor-mount kits

What We Need to Quote (Fast)

  • ^
    Amperage (frame) and available fault current (kAIC target)
  • ^
    System voltage (e.g., 480Y/277V, 208Y/120V, 600V) and frequency
  • ^
    Enclosure type (NEMA 1/3R/4/4X/12 or 7/9) and material preference
  • ^
    Neutral required? (solid or switched)
  • ^
    Accessories (GFP, ERMS/RELT/DAS/ARMS, shunt/UV trip, aux/alarm contacts, key interlocks, cam-locks)
  • ^
    Mounting & entry (top/bottom conduit, cable lugs, gland plates)
  • ^
    Any spec section or utility/authority requirements for labeling